8.7. Electric sensors

SENSOR OF LEVEL OF COOLING LIQUID

Removal

Arrangement of the sensor of level of cooling liquid on a broad tank

PERFORMANCE ORDER
1. The sensor is installed on a sidewall of a broad tank (see the drawing). You make removal of the sensor on the cold engine. Partially merge cooling liquid so that the broad tank was empty.
2. Disconnect electric sockets from the sensor of level of cooling liquid.
3. Remove a lock ring and take the sensor of level of cooling liquid from a broad tank. Remove a sealing ring.
4. Connect an ohmmeter to contacts of the sensor and measure sensor resistance.
5. If the float of the sensor is established in the top situation, contacts of the sensor have to be opened. At installation of a float in the lower situation contacts of the sensor have to become isolated.

Installation

PERFORMANCE ORDER
1. Installation is made in the sequence, the return to removal. Install a new sealing ring on the sensor case. Fill in cooling liquid in the cooling system.

SENSOR OF THE INDEX OF TEMPERATURE OF COOLING LIQUID

The sensor of the index of temperature of cooling liquid is screwed in in the top left part of a head of the block of cylinders. Do not mix it with the sensor of temperature of cooling liquid of a control system of the engine which is located a row.

Removal

PERFORMANCE ORDER
1. You make removal of the sensor on the cold engine. Partially merge cooling liquid from the cooling system.
2. Disconnect the electric socket from the sensor, unscrew the sensor from a head of the block of cylinders and remove a sealing ring.

Installation

PERFORMANCE ORDER
1. Installation is made in the sequence, the return to removal. Install a new sealing ring on the sensor. Add cooling liquid in the cooling system.