8.10.8. Regulator of size of an air stream

Removal

PERFORMANCE ORDER
1. Remove the control unit of a heater.
2. Remove an arm of fastening of the regulator from the console.
3. Remove the finishing panel under steering columns.
4. Under the dashboard remove a cable of management from the lever at the basis of a heater and take a cable from fastening brackets.
5. Move the regulator of size of an air stream to the right, take the block of the regulator and under a back part of the regulator disconnect the electric socket.
6. Take the switch from the console, stretching a cable of management via the heater block.

Installation

PERFORMANCE ORDER
1. Installation is made in the sequence, the return to removal.